Waterproofing for basement, kitchen, bathroom, underground tunnel, deep wells structure and normal decoration.
Leak-proofing and penetrating-proofing of reservoirs, water towers, swimming-pool, for Bath-pool, fountain pool, impounding reservoir, sewage cleaning pool and irrigation channel.
Used for preventing of leaking, corrosion and penetrating for water tanks, underground Pipeline.
Bonding and moisture-proofing of various floor tiles, marble, asbestos plank and so on.
All product properties and application details based on information are ensured to be reliable and accurate. But you still need to test its property and safety before application.
All advices we supply can’t be applied in any circumstances.
CHEMPU don't make assurance of any other applications outside the specification until CHEMPU supply a special written guarantee.
CHEMPU is only responsible to replace or refund if this product is defective within the warranty period stated above.
CHEMPU makes it clear that will not take responsible for any accidents.
PROPERTY WP-001 |
|
Appearance |
Grey Uniform Sticky Liquid |
Density (g/cm³) |
1.35±0.1 |
Tack Free Time (Hr) |
3 |
Adhesion Elongation |
666 |
Hardness (Shore A) |
10 |
Resilience Rate (%) |
118 |
Curing Speed (mm/24h) |
3 ~ 5 |
Elongation at Break (%) |
≥1000 |
Solid Content (%) |
99.5 |
Operation Temperature ( ℃) |
5-35 ℃ |
Service Temperature ( ℃) |
-40~+80 ℃ |
Shelf Life (Month) |
9 |
Implementation of standards: JT/T589-2004 |
Storage Notice
1.Sealed and stored in cool and dry place.
2.It is suggested to be stored at 5~25 ℃, and the humidity is less than 50%RH.
3.If the temperature is higher than 40 ℃ or the humidity is more than 80%RH, the shelf life may be shorter.
Packing
500ml/Bag, 600ml/Sausage, 20kg/Pail 230kg/Drum
The substrate should be smooth, solid, clean, dry without sharp concave and convex points, honeycomb, pocking marks, peeling, free of bulges, greasy before application.
It is better coating 2 times with scraper. When the first coat isn’t sticky, the second coat can be applied, the first layer is recommended being applied in thinner layer for better releasing gas generated during reaction. The second coat should be applied in different direction to the first coat. The optimal coating rate is 2.0kg/m² for thickness of 1.5mm.
Attention of operation
Wear suitable protective clothing, gloves and eye/face protection. After contact with skin, wash immediately with plenty of water and soap. In case of accident or if you feel unwell, seek medical advice immediately.